  • 摘要: 介绍了CM200透射电子显微镜电镜保护(LPR)的工作原理,分析了电镜保护关机的故障原因并介绍了几个维修实例.

     

    Abstract: The working principle of Lens Protection of CM200 TEM (transmission electron microscope) is described, the reasons of protective shutdown of TEM are analyzes and some maintenance examples are introduced.

     

/