对甲苯磺酸中间位、邻位同分异构体在高效液相色谱中的分离探究

Optimization and Separation of Meta- and Ortho-Isomers of p-Toluenesulfonic Acid by High-Performance Liquid Chromatography

  • 摘要: 探究高效液相色谱技术在对甲苯磺酸同分异构体(间位与邻位)分离与定量中的应用. 采用Hypercarb(3 μm,100 mm×4.6 mm)色谱柱,通过优化流动相(0.1%高氯酸水溶液/乙腈)、柱温(30 ℃)及检测波长(210 nm)等色谱条件,确立了最佳分离方案. 在梯度洗脱模式下,成功实现了对甲苯磺酸间位、邻位同分异构体的高效分离,分离度均超过1.5. 进一步基于外标法构建标准曲线,确认了间甲苯磺酸与邻甲苯磺酸分别在0.056~1.12 mg/mL和0.054~1.09 mg/mL范围内具备良好的线性相关性. 此外,通过加标回收试验验证,各异构体的回收率稳定在96%~104%之间,且相对标准偏差(RSD)为0.32%~2.02%,充分证明了在定量分析中的准确性和可靠性.

     

    Abstract: The application of high-performance liquid chromatography (HPLC) in the separation and quantification of isomers (meta- and ortho-) of p-toluenesulfonic acid was explored. The optimum separation condition was achieved on a Hypercarb (3 μm, 100 mm×4.6 mm) column by optimising the mobile phase (0.1% perchloric acid/acetonitrile), column temperature (30 ℃) and detection wavelength (210 nm). Under the gradient elution mode, the efficient separation of meta-, and ortho-isomers of p-toluenesulfonic acid were successfully achieved, with the resolution exceeding 1.5. Furthermore, the standard curves were constructed based on external standard method, which confirmed that meta-, and ortho-toluenesulfonic acid had good linear correlations in the concentration ranges of 0.056~1.12 mg/mL and 0.054~1.09 mg/mL, respectively. In addition, through the validation test with spiked recovery, the recoveries of the isomers were in the range of 96%~104%, and the relative standard deviations (RSDs) were 0.32%~2.02%, which fully proved the accuracy and reliability of the method in quantitative analysis.

     

/